Omnitek U-Visc Automatic Viscometry System( 2 Independent Baths, 1 Viscometer Tubes per Bath
Catalog/Part Number:: U-Visc 210
Description
Test
Method
Kinematic
viscosity is of primary importance in the design and selection of a wide range
of petroleum products. Calibrated capillary viscometers are used to measure
flow under gravity or vacuum at precisely controlled temperatures.
Features
·
Applicable for fuels, base oils, formulated
oils, and other petrochemical fluid chemicals as well as diluted polymers
·
Meets all ASTM, EN, ISO, and DIN standards
related to kinematic viscosity and diluted solution viscosity standards
·
Extremely accurate temperature control
·
Extremely accurate flow-time measurement
independent of fluid type
·
Viscometer filling by either vacuum or pressure
method
·
Little sample volume / little solvent
consumption
·
High Capacity; up to 10 measurements per bath per
tube per hour
·
Innovating viscometer tube cleaning allowing
cross contamination free operation
·
Easy viscometer tube exchange
·
Suitable for petrochemical fluids and diluted
solution viscosity samples
·
Chemically resistant to an extended range of
fluids and solvents
·
Multiple versions available covering a wide
variety of requirements
·
Compact design
Description
The Omnitek
U-Visc is the next generation of completely automatic viscometry systems. The
system combines several unique features, making it the instrument of choice in
many applications, ranging from QC to R&D to used oil analysis. While
offering full compliance with ASTM D445/D446, the specially designed viscometer
tubes cover a 100-fold range, e.g. from 1 to 100 mm2/s. The tubes are based on
the well-known and proven Ubbelohde design, but only require 8-16 mL of sample
and approx. 12-15 mL of solvent for cleaning. Available with single or dual
solvent cleaning, the instrument measures kinematic viscosity in Newtonian
fluids like lubricants, fuels, or dissolved plastics between 0.15 and 25,000
mm2/s.
Designed to
be versatile and flexible, yet easy to use. Different models are available from
1 bath with 1 or 2 viscometer tubes, up to 2 baths with 1 or 2 viscometer tubes
per bath, where each bath works independently. Sophisticated temperature
control ensures that measurements are carried out well within limits specified
by ASTM D445. Each bath features a 32-position sampling tray (16 samples per
tube, allowing completely unattended operation. Depending on the viscosity of
the sample, the instrument can process up to 40 measurements per hour,
satisfying even the needs of high volume labs running several hundred samples
per day.
Samples can
be introduced using vacuum or pressure. The latter avoids evaporation of
sample, which can be a point of concern in some dilute viscosity applications.
Viscometers are easily exchanged in minutes instead of hours, minimizing
downtime. All surfaced of the viscometer tubes, including the outside bottom,
which is in contact with the sample, are thoroughly cleaned and dried using
solvents and air.
Omnitek
U-Visc requires a PC for operation (not included) but can also be controlled as
a stand-alone unit through the responsive color touchscreen interface with a
storage up to 10,000 measurement results. For full data collection, storage,
calculations, and reporting, an advanced PC software application is provided
with the instrument, which can gather data from multiple instruments
simultaneously.
While using
the software during a run, several kinds of information is shown like measured
flow times, average, spread and calibration / viscosity result. Also, actual
status like filling, cleaning, etc. is shown for every unit involved. Measured
flow times are presented in left or right column, depending whether the upper
or lower measuring bulb is used for testing. Sample queue is permanently
present and can be edited any time without interrupting running samples.
Included
Accessories
·
16 Position Autosampler per Tube
·
100-fold Viscometer Tube(s)
·
Bath Oil
·
Cooling Coil
·
Reference Standards
·
Dual Solvent Injection
·
Advanced PC Software
Technical Specifications
Specifications
Conforms to
the specifications of:
ASTM D445,
D446, D2270; IP 71; ISO 3104, ISO 3105, ISO 2909; DIN 51562; FTM 791-305; NF T
60-100
Measuring
Range: 0.15 - 25,000 mm2/s @ 40 °C
Temperature
Range: 15 to 150 °C (59 - 302 °F)
Temperature
Stability: 15 - 100 °C ±0.01 °C; Up to 150 °C
±0.03 °C (*For temperatures around ambient, and external chiller is
required)
Timer
Accuracy: 0.001 s
Sample
Volume: 8 - 16 mL
Sample
Introduction: Vacuum / Pressure
Solvent
Consumption: 10 - 12 mL per cycle (single), 12 - 15 mL per cycle (double)
Sample
throughput:
U-Visc 110: Up to 10 measurements per hour
U-Visc 120: Up to 20 measurements per hour
U-Visc 210: Up to 20 measurements per hour
U-Visc 220: Up to 40 measurements per hour
** Measurements per hour depends on the
viscosity, tube, temperature and solvents chosen
Viscometer
Type: Ubbelohde based
Sensor Type:
Thermal / Optical
Communication:
RS232
PC Control:
Multiple instruments can be controlled with one PC
Data Export:
USB
Electrical
Requirements
115V 60Hz
230V 50Hz
Dimensions
U-Visc
110/120: 15 x 20 x 30.7 (38x51x78)
U-Visc
210/220: 29.5 x 24.4 x 30.7 (75x62x78)
Net Weight
U-Visc
110/120: 85 lbs (119.05kg)
U-Visc
210/220: 92 lbs (202.8kg)
Additional
Accessories
Sample
Preheating
Pedestal
Base
Cooling
Circulator (for measurement around room temperature)
Compressor
PC for
Instrument Control
Polyethylene
Sample Cups (750/pack)
Glass Sample
Cups (50/pack)
Viscometer
Tubes
Spare Parts
Kit
Zero(0) Reviews