HKV4000 High Temperature Kinematic Viscosity Bath with Integrated Digital Timing
Catalog/Part Number:: HKV4000
Description
Test Method
Kinematic viscosity is of primary
importance in the design and selection of a wide range of petroleum products.
Calibrated capillary viscometers are used to measure flow under gravity or
vacuum at precisely controlled temperatures.
Features
Microprocessor temperature
control between ambient and 232 °C (450 °F)
Integrated digital timing for
easy measurement of sample efflux times
Permits entry of viscometer
constants for automatic calculation and display in viscosity units or seconds
Dual digital displays show
setpoint and actual bath temperature
Selectable temperature scale -
Fahrenheit or Celsius
Conforms to ASTM D445, D2170 and
related specifications
Description
High temperature bath with
advanced temperature control circuitry and integrated timing features for
convenient, accurate glass capillary viscometry determinations. Microprocessor
PID circuitry assures precise, reliable temperature control within ASTM
specified tolerances throughout the operating range of the bath. Simple
push-button controls and dual digital displays permit easy setting and
monitoring of bath temperature. Two place calibration offset capability is
provided. Bath accommodates seven glass capillary viscometers of various
types. Viewing the viscometers is made
easy by glare-free LED illumination inside the bath and a baffle that provides
a background for easy viewing. Temperature control uniformity is assured by
means of motorized stirrer which provides complete circulation without
turbulence. Connection of the built-in cooling coil to tap water or a
recirculating water chiller facilitates temperature control at ambient or below
ambient temperatures. Communications software (RS232, etc.) ramp-to-set, and
other enhanced features are available at an additional cost.
Integrated Timing Features -The
user can enter the viscosity constant for each viscometer on the front Touch
Screen Control Panel, and then get the test result in both efflux time and
viscosity units automatically after stopping each timer. Timing function is
displayed in 0.01 second resolution and is accurate within 0.01%.
Bath Construction and Safety
Features - Bath chamber is a clear borosilicate glass vessel enclosed in a
polyester-epoxy finished steel housing. Top working surface has seven 2"
(51mm) viscometer ports. Front viewing window assures safe, distortion-free
viewing. Microprocessor temperature controller incorporates safety circuitry
that interrupts power to the heaters in the event of an overtemperature
condition or disconnection of the primary probe. For added safety, an
adjustable redundant controller with separate sensor probe interrupts power if
an overtemperature situation occurs. An integrated low-liquid sensor prevents
operation of the bath if the bath liquid is not filled to the proper level and
cuts off power should it fall below during operation. Both overtemperature and
low liquid level circuits will latch and prevent further operation of the bath
until the fault is removed.
Technical Specifications
Conforms to the specifications of:
ASTM D445, D2170, D6074, D6158;
IP 71, 319; ISO 3104; DIN 51550; FTM 791-305; NF T 60-100
Temperature Control Range:
ambient to 232°C (450°F); sub-ambient to 10°C with external cooling
Display: 0.1 °C / 0.1 °F
resolution, calibrate to 0.01 °C / 0.01 °F
Control accuracy and uniformity:
Exceeds ASTM requirements throughout the operating range
Timing: Integrated timing
function within Touch Screen Control Panel displayed to 0.1 seconds and
accurate within 0.01%
Communication: RS232, RS485 port
Viscometer ports: Seven round
2" (51mm) ports
Bath Medium: Water or suitable
heat transfer fluid
Bath Capacity:
12": 5.8 gal (22L)
18": 8.9 gal (33.7L)
Zero(0) Reviews