Omnitek S-Flow Automatic Houillon Viscometry System S-Flow 3500 Fully Automatic Dual Bath, Integrated Viscosity Index
Catalog/Part Number:: S-Flow 3500
Description
Test
Method
The kinematic viscosity characterizes flow behavior. This method covers the measurement of kinematic viscosity of transparent and opaque liquids, such as base oils, formulated oils, diesel oil, biodiesel blends, residual fuel oils, marine fuels, and used lubricating oils using an automated Houillon viscometer.
Features
Applicable
for fuels, base oils, formulated oils, and petroleum products as well as
water-based fluids
Compliant
with requirements for ASTM D7279, ASTM D2240, and correlation to ASTM D445
High
throughput: up to 80 samples per hour per bath under ideal operating conditions
Very easy to
use and maintain
Small sample
volume: 0.3 - 1.0 mL
Low solvent
consumption: 2 - 3 mL per sample
Extremely
accurate temperature control and flow-time measurement independent of fluid
type
Automatic
flow time measurement with ultraprecise meniscus detection
Fully
automatic cleaning and drying (model dependent)
Fast and
easy tube replacement (tubes are not connected to optical sensors)
No need to
drain bath during tube replacement
Single or
dual solvent injection (model dependent)
Integrated
Cleaning Pump
Integrated
VI calculations (on 3500 model only)
Stand-alone
unit. No PC required. Software operation is available as an option
Chemically
resistant to allow for all common solvents
Optional
duplo measurement capability
Integrated
back flushing
Optional
software available
Description
The Omnitek
S-flow range of instruments consists of compact, bench-top automated viscometry
systems for the analysis of used and new lubricants. It is also the ideal
system for used oil analysis laboratories that need to test a wide range of
lubricant viscosities. Additionally, S-flow systems are used for analysis of
fuels like diesel, bunker fuel and biofuel (feedstock), hydraulic and metal
working fluids and even gelatins and inks.
The S-flow
system is a self-contained viscometer system that consists of a thermostatic
bath with circular heater and a control touchscreen. The bath contains 4
viscometer tubes together with optical sensors to detect the flow of oil
through the tubes. All measuring tubes function independently of each other.
The system contains a touchscreen with storage up to 10,000 measurement results. The touchscreen allows the user to control and operate the system. Although a PC is not required to operate the instrument, additional software is available for LIMS connection and full data storage and reporting. The user has the option to operate in two modes, standard viscosity determination or tube calibration. In both modes, the operator chooses how many determinations must be made for an average result. Additional parameters such as tube constants and cleaning cycle are also controlled by the operator.
Because the
sample volume is very low (0.3 - 1 mL), the entire measurement cycle is very
short. After the user injects the sample into the tube, the sample travels down
towards the optical sensors and heats up to the test temperature very quickly.
Upon reaching the first sensor, the time measurement is started. When the
second sensor is reached, the measurement is stopped, and the result is
displayed on the touchscreen or through the PC software. Then, a predefined
cleaning cycle automatically commences, cleaning and drying the tubes
completely.
The entire cycle time ranges between 3 - 10 minutes per tube, allowing a throughput of up to 80 tests per hour per bath under ideal operation conditions. After the injection of the sample, operator presence is no longer required. The operator only needs to return after the system has completed the measurement and cleaned the tube.
Configuration Options
|
S-Flow 3500 VI
|
|
| Number of baths |
2
|
| Viscometers per system |
8
|
| Solvent Injection |
Automatic
|
| Integrated Viscosity Index |
Yes
|
| Dual Solvent Option |
Yes
|
| Duplo Measurement Option |
Yes
|
| Samples per hour* |
80 - 160
|
| Touchscreen |
10"
|
| Optional Robotic Operation | Yes |
Technical Specifications
Included
Accessories
Viscometer
Tube(s)
Starter Kit
Backflush
Kit
Calibration
Standards
Specifications
Conforms to
the specifications of:
ASTM D7279,
D2270 Correlates to ASTM D445
Measuring
Range: 0.3 - 3,000 mm2/s (cSt) @ 40 °C
Temperature
Range: 20 to 120 °C (68 - 248 °F) (*For temperatures around ambient, and
external chiller is required)
Temperature
Stability: Better than ±0.02 °C
Timer
Accuracy: 0.001 s
Sample
Volume: 0.3 - 1.0 mL
Solvent
Consumption: 2 - 3 mL per cycle
Sample
throughput: Up to 80 samples per hour per bath (under optimal conditions)
Viscometer
Type: Houillon
Sensor Type:
Optical
Communication:
RS232
PC Control:
Multiple instruments can be controlled with one PC
Data Export: USB
Electrical
Requirements
230V 50Hz
Dimensions
wxdxh,in.(cm)
S-Flow 870 /
1250: 17.3 x 18.9 x 24.4 (44x48x62)
S-Flow 2500 VI: 27.6 x 18.9 x 24.4 (70x48x62)
Net
Weight
S-Flow 870 /
1250: 70.5 lbs (32 kg)
S-Flow 2500 VI: 136.7 lbs (62 kg)
Additional
Accessories
Dual Solvent
Cleaning
Cooling Coil
and Circulator (for measurement around room temperature)
Compressor
PC for
Instrument Control
Robotic
Operation
EasyFlow or
Duplo Viscometer Tubes
Positive-Displacement
pipette
Software
Zero(0) Reviews