LKV5000 Refrigerated Kinematic Viscosity Bath with Optical Flow Detection System

Availablity: In stock

Catalog/Part Number: LKV5000
Brand: KOEHLER
Supplier: KOEHLER
Supplier Location: Holtsville, New York 11742, USA
Inventory Weight: unavailable
Unit of Measurement:
Inventory Brochure: unavailable

Catalog/Part Number:: LKV5000

Sorry no inventory found for this brand at this time.

Description

Test Method

Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures.

 

Features

Kinematic viscosity is of primary importance in the design and selection of a wide range of petroleum products. Calibrated capillary viscometers are used to measure flow under gravity or vacuum at precisely controlled temperatures.

 

Description

Koehler LKV5000 series kinematic viscosity baths with optical flow detection system provides automatic viscosity measurements of petroleum and petrochemical products. Includes communication and power ports for each optical detection assembly, and can utilize up to four optical assemblies. Optical sensors and viscometer tubes to be ordered separately. The bath improvements in operating features, safety and cabinetry. Advanced temperature control circuitry includes microprocessor PID design and two decimal calibration offset. Simple pushbutton controls and dual digital displays permit easy setting and monitoring of bath temperature. Bath accommodates four glass capillary viscometers using 2" (51mm) round holders (rectangular ports are available on special order). Bath medium is contained in a clear, evacuated Dewar flask, and glare-free fluorescent backlighting provides excellent visibility when working with the viscometers.

The LKV5000 operates at temperatures from ambient to -30 °C (-22 °F) or ambient to -70 °C (-94 °C), model dependent, exceeding ASTM temperature control accuracy and uniformity requirements throughout the operating range. Air-cooled hermetic compressors provide efficient operation with the use of CFC-free refrigerants.

Insulated steel cabinet has an attractive polyester-epoxy finish and is mounted on adjustable leveling feet. Chemical resistant working (top) surface has four round ports for 2" (51mm) viscometer holders and one port for a thermometer holder. Front viewing window provides clear, distortion-free visibility. Microprocessor controller incorporates circuitry that interrupts power to the heater in the event of an overtemperature condition or disconnection of the primary probe. A redundant adjustable controller and sensor probe provide added overtemperature protection, and an integrated low liquid level sensor cuts power to the heaters if the bath liquid is not filled to the proper level or falls below during operation. Both overtemperature and low liquid level circuits will latch and prevent further operation of the bath until the fault is removed.

 

Included Accessories

Port Cover, Delrin® (4),Thermometer Holder

Catalog/Part Number: LKV5000 Category:

Technical Specifications

Specifications

Conforms to the specifications of:

ASTM D445, D2170, D6074, D6158; IP 71, 319; ISO 3104; DIN 51550; FTM 791-305; NF T 60-100

Testing Capacity: Four (4) glass capillary viscometers

Viscometer Ports: Four (4) round 2" (51 mm) ports

Bath Dimensions: 9 ½" dia. x 12" depth (24 cm dia. x 30 cm)

Bath Capacity: 3.7 gal (14 L)

Temperature Range:

K22753-OS: 15 °C to -30 °C (59 °F to -22 °F)

K22754-OS: 15 °C to -30 °C (59 °F to -22 °F)

K22751-OS: 15 °C to -70 °C (59 °F to -94 °F)

K22752-OS: 15 °C to -70 °C (59 °F to -94 °F)

Temperature Control Display: 0.1 °C / 0.1 °F resolution, calibrate to 0.01 °C / 0.01 °F

Control accuracy and uniformity: Exceeds ASTM requirements throughout the operating range

 

Electrical Requirements

115V 60Hz, Single Phase, 26.9A

220-240V 50Hz, Single Phase, 14.5A

 

Dimensions

 

lxwxh,in.(cm): 42 x 35 x 36 (107x89x91)

Net Weight:

K22751-OS: 278 lbs (126.1 kg)

K22752-OS: 278 lbs (126.1 kg)

K22753-OS: 176 lbs (79.83 kg)

K22754-OS: 176 lbs (79.83 kg)

 

Additional Accessories

 

K23780-SFW-A LKV5000 Kinematic Viscosity Software Package                                    

K23780-CF Optical Sensor for Cannon®-Fenske Viscometer Tubes

378-025-C01-OS thru 378-700-C01-OS Cannon®-Fenske Viscometer Tubes, Size 25 thru 700

K23780-RF Optical Sensor for Cannon®-Fenske Opaque Reverse Flow Viscometer Tubes

378-025-C02-OS thru 378-700-C02-OS Cannon®-Fenske Opaque Reverse Flow Viscometer Tubes, Size 25 thru 700

K23780-UB Optical Sensor for Ubbelohde Viscometer Tubes

378-000-C03-OS thru 378-005-C03-OS Ubbelohde Viscometer Tubes, Size 0 thru 5

K22090 Withdrawal Bulb

K23311 Rubber Stopper for Viscometer Tube, pk/12

355-001-001 White Mineral Oil, 1 Gallon

355-001-003 White Mineral Oil, 5 Gallon

250-000-120C ASTM 120C Thermometer, 40 °C Test Temperature

250-000-121C ASTM 121C Thermometer, 100 °C Test Temperature

Add a review

You must login to make reviewLogin

  1. Zero(0) Reviews