K88990 Automatic Calorimeter
Catalog/Part Number:: K88990
Description
Test
Method
Heat of
combustion is determined in this test method by burning a weighed sample in an
oxygen pressure vessel calorimeter under controlled conditions. The heat of
combustion is computed from temperature observations before, during and after
combustion with proper allowances for thermochemical and heat transfer
corrections. Either isothermal or adiabatic calorimeter jackets can be used.
Features
Isoperibol
Calorimetry
Removable
Oxygen Pressure Vessel and Bucket 4-6 tests per hour (6 tests requires 2nd
vessel and bucket)
Operator
time per test is approximately 6 minutes
0.1% RSD
Precision Class Instrument
Accuracy:6318±19
cal/g for single analysis of standard
SD Memory
and Ethernet Network Communications
Description
The K88990
features a removable pressure vessel and bucket design. It can achieve the
highest level of precision and accuracy of any oxygen pressure vessel
calorimeter. It is a good choice for high precision quality control work and for
research and development. Multiple pressure vessel choices are also available,
expanding its functionality for higher energy releases An isoperibol
calorimeter is one where the surrounding jacket is maintained at a constant
temperature while the temperature of the pressure vessel and bucket rise as
heat is released by the combustion. The K88900 and K88990 Calorimeters are true
isoperibol calorimeters. In these implementations, a controlled temperature
jacket, completely surrounds the combustion pressure vessel and its “bucket”. A
microprocessor-based controller monitors both the temperature of the bucket and
the jacket and performs the necessary heat leak corrections that result from
differences in these two temperatures. These corrections are applied continuously
in real-time throughout the test rather than as a final correction based on pre
and post test measurements. Removable pressure vessel calorimeters are the more
traditional design most users will recognize. In this design the oxygen
pressure vessel and bucket are removed from the calorimeter for loading the
sample and filling the bucket with the carefully measured amount of water which
absorbs the energy released in the combustion.
Included
Accessories
Oxygen
Pressure Vessel, Alloy 20
Oxygen
Regulator
Calibration
Standards, Range: 5000-8000 Calorie
Maintenance
Kit for Pressure Vessel Repair
Technical Specifications
Specifications
Conforms to
the specifications of:
ASTM D240,
D1989, D4809, D5468, D5865, E711; ISO 1928; DIN 51900; AS 1038.5; BS1016; JIS
M8814
Measurement
Type: Isoperibolic
Precision
Classification: 0.05 to 0.10%
Number of
Vessels: Up to 4
Bucket
Filling / pressure vessel Washing: Manual
Oxygen
Filling: Automatic
Memory: 1000
Tests
Printer /
Balance Connection: Ethernet or USB
Network
Connection: Ethernet
Temperature Resolution: 0.0001°C
Electrical
Requirements
220-240V 50/60Hz, Single Phase, 0.2A
Dimensions
Wxdxh,in.(cm): 22.5x15.75x17 (57x40x43)
Additional
Accessories
K88900-1
Water Handling System, 115V 60Hz Includes: 2000mL Pipette, Closed Loop
Temperature Controlled Water Supply, Integral Solid State Cooling Unit
K88990-1
Water Handling System, 230V 50/60Hz
K88900-2
Printer w/ Cable
K88900-3
Service Kit, 1 year
Zero(0) Reviews