K60092-PT Automatic Heated Oil Test Centrifuge,4 Place, Pear Tube rotor Assembly
Catalog/Part Number:: K60092-PT
Description
Test
Method
Centrifugation
provides a convenient means of determining sediment and water content in crude
oil, fuel oils, middle distillate fuels, and biodiesel. Also used in
determining the precipitation number, demulsibility characteristics, trace
sediments, and insolubles in used lubricating oils.
Features
Choice of
long, short, pear, or finger rotor assembly to accommodate corresponding
centrifuge tubes
Accommodates
four (4) four centrifuge tubes of 6 or 8” conical ASTM types, long, short, pear
or finger tubes
Automatic
control of acceleration ramp, centrifugation speed, andtiming functions.
4-1/2” LCD
Touch Screen Control Panel
Substantial
Insulation for Reduced Heat Loss
Precise
balancing, Quiet Operation
Large,
clear, top opening lid
Class 1,
Division 2 explosion resistant rating
Description
Fully automatic bench top centrifuge designed expressly for petroleum
testing applications. Features a 4-1/2” LCD touch screen control panel. This
integrated touch screen can be used to turn the heat on and off, set the
duration of the test, set the RCF/RPM values and choose the type of rotor
assembly and corresponding glassware to be used during the test. The Servoed
motor speed mechanism allows the user to simply set the desired speed and the
instrument will attain that speed. This mechanism calculates RPM based on the
given RCF and type of Rotor selected. The large, clear, top opening lid
provides for easy access to the rotor and tube holders and for cleaning of the
unit. The lid has a 18-1/2” diameter viewing window allowing the operator to
view inside the chamber for checking the status of the rotor and checking for
possible spillage of the centrifuge tubes. Molded PTFE cushions provide for
maximum protection and easy positioning of the tubes. Safety Features The
Centrifuge comes equipped with a Safety Lockout Mechanism. Upon emergency
shutdown the door is locked and cannot be unlocked until the unit comes to a
complete stop, the unit is turned back on, and the stop/unlock key is pressed
on the touch screen display. Furthermore, the centrifuge cannot start while the
door of the chamber is open and the latch is not engaged. The “Nitrogen Purge”
feature allows for a slow release of Nitrogen into the bowl of the centrifuge.
This feature requires an external Nitrogen Gas source and can easily connect to
an Inlet port located at the back of the unit.
Technical Specifications
Specifications
Conforms to
the specifications of:
ASTM D91,
D96, D893, D1796, D2273, D2709, D2711, D4007, D5546; IP 75, 145, 359; API 2542,
2548; ISO 3734; DIN 51793; NF M 07-020
Capacity:
Four (4) oil test centrifuge tubes: long (100mL), short (100mL), pear (100mL),
or finger tubes (12.5mL)
Maximum
Speed: 2200 RPM
Maximum RCF:
1327 (long); 1170 (short); 865 (pear-shaped)
Timer: 0 to
999 min
Set Speed:
200 - 2200 RPM
Speed Readout:
0 - 2200 RPM
Temperature
Control: ambient to 93°C (200°F)
Temperature
Readout: Digital
Brake:
Automatic Dynamic
Electrical
Requirements
85 to 260
VAC; 48 to 62 Hz
Dimensions
lxwxh,in.(cm):
31x25.8x14.3 (78.74x65.53x36.32)
Additional
Accessories
K60002-LT-1
Rotor Assembly for Long Tubes
K61101
Centrifuge Tube, Long, 100mL, 8”, marked in mL (ASTM D91, D96, D893, D1796,
D4007)
K61106
Centrifuge Tube, Long, 100mL, 8”, marked in 200 parts (ASTM D96)
K61110
Centrifuge Tube, Long, 100mL, 8”, marked in mL every 1mL above 10ml (ASTM D96,
D4007)
K61112
Centrifuge Tube, Long, 100mL, 8”, marked in 200 parts every 2 parts above 20
parts (ASTM D96)
K61109
Centrifuge Tube, Cone-Shaped, 100mL with capillary tip capable of measuring
0.01 mL and readable by estimation to 0.005%
(ASTM D2273,
D2709) (K61153 cushion required for each tube)
K61135 PTFE
cushion for Long Tubes
K61153 PTFE
cushion for Long Tubes with capillary tip (Required for K61109 tubes)
K60002-ST-1
Rotor Assembly for Short Tubes
K61102
Centrifuge Tube, Short, 100mL, 6”, marked in 200 parts every 4 parts above 20mL
(ASTM D96)
K61105
Centrifuge Tube, Short, 100mL, 6”, marked in mL (ASTM D96)
K61107
Centrifuge Tube, Short, 100mL, 6”, marked in mL every 2mL above 10mL (ASTM D96)
K61108
Centrifuge Tube, Short, 100mL, 6”, marked in 200 parts (ASTM D96)
K61146 PTFE
cushion for Short Tubes
K60002-PT-1
Rotor Assembly for Pear Tubes
K61104
Centrifuge Tube, Pear, 100mL, marked in mL
K61152
Centrifuge Tube, Pear, 100mL, with tube tip having graduations of 0.01mL over
the range 0 to 0.2mL (ASTM D2709)
K61111 Cork
Stopper for Long, Short and Pear Tubes
K60002-FT-1
Rotor Assembly for Finger Tubes
K61141
Centrifuge Tube, Finger Tube (API 2542)
K61136 Felt
support for Finger Tube
K61132 Cork Stopper for Finger Tub